KAM CSS Complete Sampling System
Customized to fit each application, the KAM Complete Sampling Solution includes one of our patented mixing elements to ensure homogeneity, an ultrasonic flow meter, an isokinetic automatic sampler, a sampler controller, a sample receiver and a KAM OWD OIL Water detector.
The KAM IAS Isokinetic Automatic Sampler features the simplest design in the industry and is the ideal instrument for pipeline sampling during custody transfer. The IAS sampler’s high degree of accuracy and simplicity facilitate extracting a representative sample, regardless of viscosity, pressure, or flow rate.
Working with the KAM SC Sampler Controller and the KAM UFM Ultrasonic Flow Meter, the IAS sampler easily extracts a representative sample from your pipeline into a KAM SR Sample Receiver. With a KAM CSM Circulating Sample Mixer, you may then mix and analyze the sample for custody transfer, API gravity measurements, shrinkage, chemical composition, etc.
The addition of the KAM OWD Oil Water Detector allows for real-time, net-oil data.
COMPONENTS
| KEY KAM ADVANTAGES
| APPLICATIONS
|
KAM CSS Complete Sampling System - Specifications
SYSTEM SPECIFICATIONS
| Media: | Crude oil, refined products, chemicals, water and wastewater |
| Material: | Wetted parts - 316 stainless steel |
| Fluid temperature: | -40o to 250oF (-40o to 125oC) |
| Electronics temperature: | -40o to 160oF (-40o to 70oC) |
| Pressure ratings: | ANSI 150, 300, 600, 900 |
IAS ISOKINETIC AUTOMATIC SAMPLER
| Power: | Air pneumatic, hydraulic |
| Sample size: | 0.5ml-2.5ml |
| Repeatability: | Exceeds API 8.2 |
SC SAMPLER CONTROLLER
| Inputs: |
Flowmeter pulse Sampler verification Meterizer pulse input Pressure Temperature |
| Interface: |
RS 232 PC interface software |
UFM ULTRASONIC FLOW METER
| Accuracy: | 1% of full range |
| Turn down ratio: | 100:1 (0.3-30 ft/sec) |
| Output: |
1 pulse per barrel 1000 pulses per barrel or optically isolated output |
OWD OIL WATER DETECTOR
| Accuracy: | 1% of full range |
| Repeatability: | ± .01% |
| Resolution: | ± .01% |
| Minimum water detection: | 100 ppm |
SR SAMPLE RECEIVER
| Volume: |
KAM SR03 - 3 Gallons (11.4 L) KAM SR05 - 5 Gallons (18.9 L) KAM SR10 - 10 Gallons (37.8 L) KAM SR15 - 15 Gallons (56.8 L) |
| Pressure: | Design - 130 psig |
| Material: | Stainless steel with viton lip seals |
| Inlet: | 1⁄2" Male quick connect |
| Outlet: | 3⁄4" Male quick connect |
| Dimensions: |
KAM SR03 - 8.25” diameter x 17.75” high (210mm x 451mm) KAM SR05 - 8.25” diameter x 25.75” high (210mm x 654mm) KAM SR10 - 12.25” diameter x 25.75” high (311mm x 654mm) KAM SR15 - 12” diameter x 41” high (305mm x 1041mm) |
| Weight: |
KAM SR03 – 7 lbs (3.2kg) KAM SR05 – 9 lbs. (4kg) KAM SR10 – 11 lbs. (5kg) KAM SR15 – 34 lbs. (15.4kg) |
CSM CIRCULATING SAMPLE MIXER
| Pump: | Gear pump – 4GPM (16LPM) |
| Motor: | Explosion proof, 1/2 HP, 110/220 VAC, 50/60 hz |
| Suction: | 3/4" female quick connect |
| Discharge: | 1/2" female quick connect |
| Sample draw-off: | 1/4" valve with tubing connection |
| Dimensions: | 23” x 12” x 14” (584mm x 305mm x 356mm) |
| Weight: | 70 lbs. (32 kg) |
KAM CSS Complete Sampling System - Documentation
Literature
- KAM OWD Oil Water Detector Literature
- KAM IAS Isokinetic Automatic Sampler Literature
- KAM UFM Ultrasonic Flow Meter Literature
- KAM SC Sampler Controller Literature
- KAM CSM Circulating Sample Mixer Literature
- KAM SMP Static Mixing Plate Literature
- KAM SMS Static Mixing Spool
Manuals
- KAM OWD Oil Water Detector Manual
- KAM UFM Ultrasonic Flow Meter Manual
- KAM IAS Isokinetic Automatic Sampler Manual
- KAM SC Sampler Controller Manual
- KAM SR Sample Receiver Manual
- KAM CSM Circulating Sample Mixer Manual
User Experience
- Lake Charles Terminal
- Marine Unloading Sampling
- Marine Unloading Sampling (2)
- Marine Unloading Sampling (3)