LKF™ Karl Fischer Moisture Analyzer - Lab Model
Compact footprint specially designed for laboratory use
The KAM KF Karl Fischer for Determining Moisture in Ethanol and Hydrocarbon Blends
The KAM KF Karl Fischer Moisture Analyzer is a key instrument for detecting low quantities of water in ethanol and hydrocarbon blends per ASTM D7923. Using the coulometric method, the KAM KF meets both repeatability and reproducibility requirements for the standard.
The KAM KF Karl Fischer for Determining Moisture in Biodiesel
Because biodiesel is far more susceptible to water absorption/contamination vs standard diesel, the KAM KF Karl Fischer Moisture Analyzer is key in detecting such contamination in sample analysis per ASTM E1064. Water contamination can come from improper fuel handling or condensation, and it can lead to microbial growth causing issues in storage and equipment, in particular, fuel injection systems. Using the preferred coulometric method, the KAM KF meets both repeatability and reproducibility requirements for the standard.
The unit comes in both portable and laboratory models and uses standard KAM Reagents and accessories in both of these applications. Steps for sampling handling, volume, etc. per ASTM D7923 and ASTM E1064 should be observed at all times. KAM has been manufacturing Karl Fischer coulometric titrators for over 30 years for a wide variety of field and laboratory applications.
CLICK HERE for quick instructions on how to measure water in crude oil using our Karl Fischer
Related Links:
ASTM DE1064 Standard Test Method for Water in Organic Liquids by Coulometric Karl Fischer Titration
Download KF Software:
Kam Moisture Analyzers incorporate the coulometric principle applied to Karl Fischer titration. Karl Fischer titrimetry is an accurate moisture measurement method utilizing the quantitative reaction of water with iodine.
Method: | Coulometric Karl Fischer titration |
Detection: | Polarization detection |
Control: | Automatic electrolysis current control |
Display: | 320 x 240 pixel LCD |
Sample size: | 0.1, 0.25, 0.5, 1.0 ml for direct reading of volume % H2O, or less than 2 grams (or ml) |
Range: | 10 μg – 100,000 μg H2O (i.e. for a 100 μg sample, the direct display is 0.0010% to 10% H2O) |
Sensitivity: | 1 μg H2O |
Repeatability: | Meets or exceeds ASTM E1064 and D7923 |
Reproducibility: | Meets or exceeds ASTM E1064 and D7923 |
Titration speed: | 1000 μg H2O/min. (max. at high H2O concentrations) |
Power requirements: | Operates on either AC or DC. AC – 110/120, 220/240 V, 50/60Hz, DC – 12V Rechargeable battery for portable model |
Ambient temp.: | 5°C – 40°C |
Dimensions: | Portable 15.5” x 8”x 10” (394mm x 203mm x 254mm) Lab 10.5″ x 8″ x 9″ (267mm x 203mm x 229mm) |
Weight: | Portable model – approx. 20 lbs. (9 kg) Lab model – approx. 10 lbs. (4.5 kg) |
Compact footprint specially designed for laboratory use
Fully portable with a rugged design suitable for the field, a rechargeable battery life of 16 hours, and storage for all required consumables.