E-IAS Electric Isokinetic Automatic Sampler

Overview

E-IAS™ with 1.25″ NPT mounting

The KAM E-IAS™ is our electric-drive automatic sampler. Ideal for LACT or other custody transfer applications, the E-IAS™ offers time-based or flow-proportional sampling without pneumatic or hydraulic drive requirements.

The E-IAS™ is based off of the same precision probe design as KAM's pneumatic IAS™ Isokinetic Automatic Sampler, which has been in operation for over 30 years. Both are fully compliant with API MPMS 8.2/ASTM D4177 and ISO 3171.

The E-IAS™:

  • can take up to 20 samples per minute, with sample bite sizes of 0.5 to 2 cc's
  • can be installed on lines up to 36"
  • model/mounting options include insertable-retractable, 1.25" NPT fixed insertion, flanged fixed insertion, or flow-through spool
  • features a positive displacement design better suited for high-paraffin applications

The E-IAS™ can be ordered with the KAM CSS™ Complete Sampling System, which also includes a pipeline mixer, a Sampler Controller, a Sample Receiver, a Weight Scale or Meterizer, and a Circulating Sample Mixer.

All delivered with the same quality and quick service that has made KAM a sampling industry leader for over 37 years.

The KAM E-IAS™ is a part of a suite of instruments designed for LACT units and other custody transfer applications which also includes the SMP™ Static Mixing Plate and the LRW™ Low Range Watercut meter.

CLICK HERE to learn more about automatic sampling systems.

CLICK HERE to contact us with questions or sales inquiries.

Related Links:

API MPMS Chapter 8.2 Automatic Sampling Standard

ASTM D1447 Automatic Sampling Standard

ISO 3171 Automatic Pipeline Sampling Standard


 

APPLICATIONS

  • LACT units
  • Truck loading, unloading
  • Marine loading, unloading

MODELS

  • Flow Through: 1 and 2″ flanged spool
  • Fixed Insertion: 1.25″ NPT (3″ to 8″ lines)
  • Insertable: 2, 3 and 4” flanged seal housing
    2” MNPT flanged seal housing (lines over 8″)

KEY ADVANTAGES

  • Ideal for LACT units and other custody transfer
  • Fully compliant with API Chapter 8.2
  • Quick lead times
  • No pressure equalization valve required
  • Flow through, flanged and MNPT process connections
  • Complete system components and mixing available

Specifications

Media: Liquid hydrocarbons, including crude oil and condensate
Materials: Wetted parts- SS316*, PEEK
Standard O-rings Viton
Bite size: 0.5, 1, 1.5 or 2 cc
Sample rate: 20 samples per minute max.
Viscosity: 1-500 cSt
Max. Process pressure: 285 psi
Process temperature: -40ºF to 350ºF (-40ºC to 177ºC)
Ambient temperature: -4ºF to 113ºF (-20ºC to 45ºC)
Pipe size: 1 – 36”
Weight: From 30 lbs (13.6 kg)
Motor: High-torque stepper motor
Electrical requirements: 120 VAC 2.0A RMS
50/60 Hz single phase
-4ºF to 113ºF (-20ºC to 45ºC)
Sampler actuation: Electrical
Industry standards: API 8.2, ASTM D4177 and ISO 3171
Safety Approval: UL Class I, Division 1, Groups C and D

* Seal Housing for 2″ MNPT Models are Carbon Steel.

Models

Documentation

Related Items

Get a quote

KAM CSS Application Data sheet

  • DD slash MM slash YYYY
  • Pipeline and installation type (please specify units)
  • Flow Conditions

    Please note: proper mixing in accordance with API MPMS Chapter 8.2 is required for accurate results. In order for KAM to properly quote a CSS, please fill out all flow conditions fields to the best of your ability. Should pipeline mixing be required, the quote will include an appropriate solution to fulfill this requirement (SMP Static Mixing Plate, SMS Static Mixing Spool or ML Measurement Loop).

  • Please mark all integrated devices in sample loop:
  •  

  • Sampling requirements (specify units)

  • Preferred Process Connection

Best for LACT Units 3" and above
  •  

Best for large diameter pipelines
  •  

  •  

Best for 2" LACTs
  •  

  • System Configuration Data
  •  

  • This field is for validation purposes and should be left unchanged.